System Components OI: BK MIKRO 7
Page 6 of 32 Rev. 2.01 dated 05.02.2007
2.1.3 Connections
Power supply
"24 VDC" model:
"+" 24 VDC terminal
Supply voltage input 24 VDC
"–" 24 VDC terminal
Reference potential of 24 VDC supply voltage
"120 VAC" and "230 VAC" models
2)
:
"L1" terminal
Supply voltage input,
depending on model: 120 VAC or 230 VAC
"N" terminal
Supply voltage input,
depending on model: 120 VAC or 230 VAC
"+" 24 VDC terminal
Control voltage for "Start" and "Teach" controlling inputs
24 VDC unregulated, output current 0.1 A max.
If an external control voltage is applied, this terminal is not connected.
"–" 24 VDC terminal
When using the internal control voltage, this terminal must be connected to the "Com"
control inputs terminal.
If an external control voltage is applied, this terminal is not connected.
Note:
2)
Alternatively, "120 VAC" and "230 VAC" models may also be supplied with
24 VDC.
In this case, "L1" and "N" terminals must not be connected.
"+24 VDC" and "–24 VDC" terminals are to be connected as described above
for "24 VDC" model.
Caution
Note:
The secondary voltage (24V) of the 120/230V Versions can be used to supply
the control inputs. It is not allowed to supply other accessories which are located
outside the overall enclosure.
Control inputs
"Com" terminal
Reference potential for control inputs and selection inputs
"Start" terminal
An input level of +24 VDC relative to "Com" terminal will trigger a "Start" cycle
(the real scanning process).
"Teach" terminal
An input level of +24 VDC relative to "Com" terminal will trigger a learning cycle
(the "Teach-in").