System Components OI: BK MIKRO 7
Page 8 of 32 Rev. 2.01 dated 05.02.2007
Relay outputs
The terminals have been designed as dry relay contacts. By switch selection, they may be
configured as either normally open or normally closed.
The contacts have been designed for 250 VAC and, by additional internal circuits, protected
against inductive switch-off peaks of up to 19 W (2 ms).
 "K.O." relay terminals
These two terminals are used to indicate a fault message (K.O.).
 "O.K." relay terminals
These two terminals are used to indicate a no fault message, i.e. a good cycle (O.K.).
Note:
Relay as normally closed contact: active = open
inactive = closed
Relay as normally open contact: active = closed
inactive = open
When there is no power to the unit, the contacts always will be open.
Even when using relay as normally closed, they are open (like the active status)
when the power supply is not connected.
2.1.4 Light-emitting diodes
Three light-emitting diodes (LEDs) on the front panel provide information about the current status
of the BK MIKRO 7 monitoring system:
 Power supply / Status
Yellow LED to indicate supply voltage and status
 "K.O." relay
Red LED to indicate fault message
 "O.K." relay
Green LED to indicate no fault message
 Error messages
Flashing red and green LED to indicate illegal switch settings and incorrect selection inputs
Fig. 2-3: Control unit Light-emitting diodes