OI: BK MIKRO 7 System Components
Rev. 2.01 dated 05.02.2007 Page 7 of 32
Selection inputs
"S1" terminal
"S2" terminal
"S3" terminal
The input signal (static) of +24 VDC relative to "Com" terminal must be stable during 10 ms min.
before "Teach" or "Start".
The input S3 must be connected at a wand length of 250 mm. Concerning shorter wands,
S3 remains unconnected. By connecting S3, the wand is slower and therefore it oscillates less.
S1/S2 selection inputs determine scanning direction!
The direction of scanning depends on connected scanner with corresponding switch position.
The meaning of "Clockwise/Counter-clockwise" toggle switch position on control unit may be
changed by corresponding S1/S2 input signals.
S1 and S2 may be open. Then is: S1=0, S2=0.
Scanner TK7A Scanner TK7RL
S1 S2 „CW/CCW“
Scanning Scanning
setting
0 0 R
CW CW-CCW
0 0 L CCW CCW-CW
1 0 R CW CW
2)
1 0 L CW
1)
CW
1)
2)
0 1 R CCW
1)
CCW
1)
2)
0 1 L CCW CCW
2)
1 1 R CCW
1)
CCW-CW
1)
1 1 L CW
1)
CW-CCW
1)
Note:
Default setting: S1 and S2 are not connected.
1)
Scanning direction differs from "CW/CCW" switch setting:
S1/S2 inputs change meaning of toggle switch.
2)
Stop position must be defined by a “Teach-in” in both directions or by a
reference procedure in both directions. Missing stop position causes an
error message, and pulses on control inputs are ignored.