B&K 2250 Light Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Medição, teste e controlo B&K 2250 Light. 2250 Hand Held Analyzer - Architecture, Design and Planning Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 122
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Technical
Documentation
HEADQUARTERS: DK-2850 Nærum · Denmark · Telephone: +45 4580 0500 · Fax: +4545801405 · www.bksv.com · info@bksv.com
Australia (+61) 2 9889-8888 · Austria (+43) 1 865 74 00 · Brazil (+55)11 5188-8166 · Canada (+1) 514 695-8225
China (+86)10 680 29906 · Czech Republic (+420)2 67021100 · Finland (+358)9-755 950 · France (+33)16990 71 00
Germany (+49) 421 17 87 0 · Hong Kong (+852) 25487486 · Hungary (+36) 1 215 83 05 · Ireland (+353)1807 4083
Italy (+39) 0257 68061 · Japan (+81) 3 37798671 · Republic of Korea (+82)23473 0605 · Netherlands (+31)318 55 9290
Norway (+47)66 77 11 55 · Poland (+48)228167556 · Portugal (+351)214711 4 53 · Singapore (+65)3774512
Slovak Republic (+421) 25 443 0701 · Spain (+34) 916590820 · Sweden (+46)8449 8600 · Switzerland (+41) 1 880 7035
Taiwan (+886)2 2502 7255 · United Kingdom (+44)1438739000 · USA (+1) 800 332 2040
Local representatives and service organisations worldwide
Hand-held Analyzer Type 2250
With 2250 Sound Level Meter Software BZ 7222 and
2250 Frequency Analysis Software BZ 7223
English BE 1712 11
Instruction Manual
BE1713-11_Cover.fm Page 1 Friday, April 16, 2004 10:57 AM
Vista de página 0
1 2 3 4 5 6 ... 121 122

Resumo do Conteúdo

Página 1 - Documentation

TechnicalDocumentationHEADQUARTERS: DK-2850 Nærum · Denmark · Telephone: +45 4580 0500 · Fax: +4545801405 · www.bksv.com · [email protected] (+61

Página 2 - Hand-held Analyzer Type 2250

CHAPTER 1Introduction5Table 1.1Components in-cluded with Type 2250QuantityBrüel & Kjær Type/Part NumberDescription1 Type 4189 Prepolarized Free-fi

Página 3 - Safety Considerations

APPENDIX ATables95Table A.39 Directional response for Hand-held Analyzer Type 2250 (including Microphone Type 4189), with Wind-screen UA 1650 fitted a

Página 4 - Table of Contents

Hand-held Analyzer Type 2250 –Instruction Manual96Table A.40 Sensitivity variations of Hand-held Analyzer Type 2250 (including Microphone Type 4189)

Página 5

APPENDIX ATables97Table A.41 Influence of Outdoor Microphone Kit UA 1404 on the directional response of Microphone Type 4189only, with Outdoor Microph

Página 6 - Chapter 1

Hand-held Analyzer Type 2250 –Instruction Manual98Table A.42 Influence of Outdoor Microphone Kit UA 1404 on the directional response of Microphone Typ

Página 7 - 1.2 System Overview

APPENDIX ATables99Table A.43 Influence of Outdoor Microphone Kit UA 1404 on the directional response of Microphone Type 4189only, with Outdoor Microph

Página 8 - 1.3 Hardware Setup

Hand-held Analyzer Type 2250 –Instruction Manual100Table A.44 Directional response for Microphone Type 4189 only, with Outdoor Microphone Kit UA 1404

Página 9

APPENDIX ATables101Table A.45 Directional response for Microphone Type 4189 only, with Outdoor Microphone Kit UA 1404 fitted,4000 Hz – 10600 Hz.Freque

Página 10 - CHAPTER 1

Hand-held Analyzer Type 2250 –Instruction Manual102Table A.46 Directional response for Microphone Type 4189 only, with Outdoor Microphone Kit UA 1404

Página 11

APPENDIX ATables103Table A.47 Sensitivity variations of Microphone Type 4189 only and Outdoor Microphone Kit UA 1404 fitted, atsound incidence angles

Página 12 - Chapter 2

Hand-held Analyzer Type 2250 –Instruction Manual104BE171211.book Page 104 Thursday, May 27, 2004 1:01 PM

Página 13 - 2.5 Measured Quantities

Hand-held Analyzer Type 2250 –Instruction Manual6BE171211.book Page 6 Thursday, May 27, 2004 1:01 PM

Página 14 - IEC 61672 – 1, Ta

105Appendix BCross-references to StandardsB.1 IntroductionThis chapter provides cross-references between specific paragraphs in the standards that req

Página 15 - Exponential time

Hand-held Analyzer Type 2250 –Instruction Manual106IEC 60651StandardParagraphSectionThis Manual’sSectionUser ManualBE 1713-113.6 4.53.7 4.43.8 4.43.9

Página 16 - CHAPTER 2

APPENDIX BCross-references to Standards107IEC 60804StandardParagraphSectionThis Manual’sSectionUser ManualBE 1713-113.7 4.43.11 4.5, 4.6.6, 4.23.12 4.

Página 17 - ∆t where:

Hand-held Analyzer Type 2250 –Instruction Manual108IEC 61260StandardParagraphSectionThis Manual’sSectionUser ManualBE 1713-113.13 4.113.18 4.43.19 4.4

Página 18 - 2.5.4 Spectrum Measurements

APPENDIX BCross-references to Standards109IEC 61672-1StandardParagraphSectionThis Manual’sSectionUser ManualBE 1713-115.1.4 25.1.5 4.25.1.6 4.5 2 - 8,

Página 19

Hand-held Analyzer Type 2250 –Instruction Manual1109.2.4 c) 59.2.4 d) 4.6.49.2.5 a) 4.59.2.5 b) 2, Appendix A9.2.5 c) 4.99.2.5 d) 2.29.2.5 e) 4.169.2.

Página 20 - Chapter 3

APPENDIX BCross-references to Standards111B.3 Irrelevant TopicsThis section provides a list of the cross-references to topics that are not provided in

Página 21 - 3.6 EMC test procedures

Hand-held Analyzer Type 2250 –Instruction Manual112BE171211.book Page 112 Thursday, May 27, 2004 1:01 PM

Página 22 - 3.6.4 Accessories

113IndexNumerics1/1-Octave-band Centre Frequencies... 451/3 Octave-band Cente Frequencies ... 461/3 O

Página 23

Hand-held Analyzer Type 2250 –Instruction Manual114Influence from the Operating Environment...47Input Socket...

Página 24 - Chapter 4

7Chapter 2Measured Quantities and Parameters2.1 IntroductionThis chapter contains detailed information on the measured quantities and parameters that

Página 25 - 4.6 Frequency Response

INDEX115Testing 1/1 Octave-band and 1/3 Octave-band Filters . 16Testing EMC According to IEC 60804 ... 17Testing Immunity Accor

Página 26 - CHAPTER 4

Hand-held Analyzer Type 2250 –Instruction Manual116BE171211.book Page 116 Thursday, May 27, 2004 1:01 PM

Página 27 - 4.6.3 Low-frequency Responses

TechnicalDocumentationHEADQUARTERS: DK-2850 Nærum · Denmark · Telephone: +454580 0500 · Fax: +454580 1405 · www.bksv.com · [email protected] (+61

Página 28

Hand-held Analyzer Type 2250 –Instruction Manual82.3 Measuring at Low Static PressureThe frequency response of the microphone depends on the static pr

Página 29

CHAPTER 2Measured Quantities and Parameters9• x is A for A-weighted, C for C-weighted or Z for Z-weighted• y is F for Fast-weighted or S for Slow-weig

Página 30

Hand-held Analyzer Type 2250 –Instruction Manual10• τ is the exponential time constant in seconds for time weighting F or S• ξ is a dummy variable of

Página 31 - 4.7 Directional Response

CHAPTER 2Measured Quantities and Parameters11• ∆t is the display update interval, equal to 1 secondThe sound pressure level is, in other words, update

Página 32

Hand-held Analyzer Type 2250 –Instruction Manual12• y is F for Fast-weighted, S for Slow-weighted or I for Impulse-weighted• T is the start time of th

Página 33

CHAPTER 2Measured Quantities and Parameters13The symbols used on the screen of Type 2250 for equivalent continuous I-weighted sound levels are(for A,

Página 34

Hand-held Analyzer Type 2250 –Instruction Manual14BE171211.book Page 14 Thursday, May 27, 2004 1:01 PM

Página 35 - Table A.25

BE 1712−11May 2004Hand-held Analyzer Type 2250with 2250 Sound Level Meter Software BZ 7222and2250 Frequency Analysis Software BZ 7223From Serial Numbe

Página 36

15Chapter 3Conformance Testing3.1 IntroductionThis chapter contains the information needed to conduct conformance testing according to the specifiedst

Página 37 - Table A.32

Hand-held Analyzer Type 2250 –Instruction Manual163.5 Testing 1/1-octave-band and 1/3-octave-band FiltersWhen testing the octave-band filter sets acco

Página 38

CHAPTER 3Conformance Testing17Fig.3.2Reference orientation of Type 2250 relative to the RF-emitter/receiver3.6.3 Securing of Microphone Cables during

Página 39 - Table A.34 to Table A.36

Hand-held Analyzer Type 2250 –Instruction Manual184) Start the measurement and let it run during test.Immunity as Sound Level MeterThe highest Suscept

Página 40

19Chapter 4Specifications4.1 SpecificationsSpecifications are given for the configuration detailed in Chapter 1.Unless specifically noted, specificati

Página 41

Hand-held Analyzer Type 2250 –Instruction Manual204.4 Reference Conditions for Acoustic CalibrationReference range: Only one range exists and this is

Página 42 - Table A.44 to Table A.46

CHAPTER 4Specifications21Fig.4.1 Electrical frequency response of Hand-held Analyzer Type 2250 with the Microphone Type parameter setto ‘Unknown’ (in

Página 43

Hand-held Analyzer Type 2250 –Instruction Manual224.6.3 Low-frequency ResponsesFig.4.3 Low-frequency response of Hand-held Analyzer Type 2250 (includi

Página 44 - 4.8 Self-generated Noise

CHAPTER 4Specifications23Fig.4.5 Influence of Hand-held Analyzer body on free-field response for Hand-held Analyzer Type 2250 (includingMicrophone Typ

Página 45

Hand-held Analyzer Type 2250 –Instruction Manual24Fig.4.8 Free-field frequency response of Hand-held Analyzer Type 2250 (including Microphone Type 418

Página 46 - 4.9 Measuring Range

TrademarksMicrosoft and Windows are registered trademarks of Microsoft Corporation in the United States and/or other coun-tries.Pentium is a registere

Página 47 - 4.9.7 Linear Operating Range

CHAPTER 4Specifications25Fig.4.10 Diffuse-field frequency response for Hand-held Analyzer Type 2250 (including Microphone Type 4189), orMicrophone Typ

Página 48 - 4.10 Detectors

Hand-held Analyzer Type 2250 –Instruction Manual264.6.6 Free-field Frequency Responses for Diffuse-field Calibrated InstrumentsAccording to IEC 60651

Página 49 - 4.10.3 Peak

CHAPTER 4Specifications27Fig.4.13 Directional response for Microphone Type 4189 only. See Table A.10 to Table A.12. -25-20-15-10-505dB0°30°60°90°120°1

Página 50 - 4.11 Spectrum Analysis

Hand-held Analyzer Type 2250 –Instruction Manual28Fig.4.14 Sensitivity variations of Microphone Type 4189 (only) at sound incidence angles within ±θ°

Página 51 - 4.11.3 Linear Operating Range

CHAPTER 4Specifications29Fig.4.15 Directional response for Hand-held Analyzer Type 2250 (including Microphone Type 4189) measured in aplane parallel t

Página 52 - 4.11.4 Measurement Range

Hand-held Analyzer Type 2250 –Instruction Manual30Fig.4.16 Directional response for Hand-held Analyzer Type 2250 (including Microphone Type 4189) meas

Página 53 - Magnetic Fields

CHAPTER 4Specifications31Fig.4.17 Sensitivity variations of Hand-held Analyzer Type 2250 (including Microphone Type 4189) at soundincidence angles wi

Página 54 - 4.14.2 Headphones Socket

Hand-held Analyzer Type 2250 –Instruction Manual32Fig.4.18 Directional response for Microphone Type 4189 only, with Windscreen UA 1650 fitted, see Tab

Página 55 - 4.17 Real-time Clock

CHAPTER 4Specifications33Fig.4.19 Sensitivity variations of Microphone Type 4189 only, with Windscreen UA 1650 fitted, at sound incidenceangles withi

Página 56

Hand-held Analyzer Type 2250 –Instruction Manual34Fig.4.20 Directional response for Hand-held Analyzer Type 2250 (including Microphone Type 4189), wit

Página 57

Table of ContentsCHAPTER 1Introduction...

Página 58 - Appendix A

CHAPTER 4Specifications35Fig.4.21 Directional response for Hand-held Analyzer Type 2250 (including Microphone Type 4189), withWindscreen UA 1650 fitte

Página 59

Hand-held Analyzer Type 2250 –Instruction Manual36Fig.4.22 Sensitivity variations of Hand-held Analyzer Type 2250 (including Microphone Type 4189) and

Página 60

CHAPTER 4Specifications37Fig.4.23 Directional response for Microphone Type 4189 only, with Outdoor Microphone Kit UA 1404 fitted, seeTable A.44 to Tab

Página 61

Hand-held Analyzer Type 2250 –Instruction Manual38Fig.4.24 Sensitivity variations of Microphone Type 4189 only and Outdoor Microphone Kit UA 1404 fitt

Página 62

CHAPTER 4Specifications394.8 Self-generated NoiseSelf-generated noise is given for nominal microphone Open Circuit Sensitivity.4.8.1 Maximum Broadband

Página 63

Hand-held Analyzer Type 2250 –Instruction Manual40Fig.4.25 Typical self-generated noise, 1/1-octave bandFig.4.26 Typical self-generated noise, 1/3-oct

Página 64

CHAPTER 4Specifications414.9 Measuring RangeNote: Type 2250 has a single measuring range. The instrument, therefore, has no measuring range (orlevel r

Página 65 - angle of incidence to

Hand-held Analyzer Type 2250 –Instruction Manual424.9.4 Indicator RangeIndicator Range according to the International Standard IEC 60804:4.9.5 Lineari

Página 66

CHAPTER 4Specifications434.9.8 Peak C RangePeak C Range according to the International Standard IEC 61672-1 is: 143 – 31.3 dB4.10 DetectorsDisplay-upd

Página 67

Hand-held Analyzer Type 2250 –Instruction Manual44Response to tone bursts for exponential averaging detectors according to IEC 60651 and DIN 45657:Not

Página 68

APPENDIX BCross-references to Standards... 105B.1

Página 69 - ‘UA 1404’

CHAPTER 4Specifications454.11 Spectrum AnalysisNote: Spectrum analysis requires Frequency Analysis Software BZ 7223.Analytical filter design: Optimise

Página 70

Hand-held Analyzer Type 2250 –Instruction Manual464.11.2 1/3-Octave band Cente FrequenciesNominal: 6.3 Hz1, 8.0 Hz1, 10 Hz1, 12.5 Hz, 16 Hz, 20 Hz, 25

Página 71 - A.4 Directional Responses

CHAPTER 4Specifications47Below the Lower Limit, the Level Linearity Error is less than or equal to the error found in Fig.2.1with Linh set to the Lowe

Página 72

Hand-held Analyzer Type 2250 –Instruction Manual484.12.1 Environmental Stabilisation TimeTypical stabilisation time after change in environmental cond

Página 73

CHAPTER 4Specifications494.13 Electrical Input to Connector Panel of Type 22504.13.1 Input Socket (Rear Socket)Triaxial Lemo socket used for Direct in

Página 74

Hand-held Analyzer Type 2250 –Instruction Manual504.15 Power Supply4.15.1 External Power to InstrumentSupply Voltage: 8 – 24 V DC, ripple voltage <

Página 75

CHAPTER 4Specifications514.18 CE-mark and C-Tick mark Compliance CE-mark indicates compliance with the EMC Directive and Low Voltage Directive. C-Tick

Página 76

Hand-held Analyzer Type 2250 –Instruction Manual52BE171211.book Page 52 Thursday, May 27, 2004 1:01 PM

Página 77

53Appendix ATablesA.1 Electrical Frequency Responses Table A.1 Electrical frequency response with the Microphone Type parameter set to ‘Unknown’ (in t

Página 78

Hand-held Analyzer Type 2250 –Instruction Manual541600 1584.89 0.98 –0.09 0.00 0.00 0.00 0.001700 1678.80 1.05 –0.10 0.00 0.00 0.00 0.001800 1778.28 1

Página 79

1Chapter 1Introduction1.1 About This ManualThis Instruction Manual for Hand-held Analyzer Type 2250, together with User Manual BE 1713, havebeen creat

Página 80

APPENDIX ATables55A.2 Free-field Frequency ResponsesFrequency responses for plane progressive sinusoidal sound waves incident from the reference direc

Página 81

Hand-held Analyzer Type 2250 –Instruction Manual56Nominal Exact (6 digits) Micr. Actuator Micr. FF Electrical Acoustical ExpandedFrequency Frequency

Página 82

APPENDIX ATables57Table A.3 Free-field frequency response of Hand-held Analyzer Type 2250 (including Microphone Type 4189) andsound field at 0° angle

Página 83

Hand-held Analyzer Type 2250 –Instruction Manual58Nominal Exact Acoustical Expanded Body Expanded Acoustical ExpandedFrequency Frequency Response Unce

Página 84

APPENDIX ATables59Nominal Exact Microphone Expanded Influence of Expanded Electrical Acoustical ExpandedFrequency Frequency Free-field Uncertainty Wi

Página 85

Hand-held Analyzer Type 2250 –Instruction Manual60Nominal Exact Acoustical Expanded 2250 Body Expanded Acoustical ExpandedFrequency Frequency Response

Página 86

APPENDIX ATables61Nominal Exact Microphone Expanded Influence of Expanded Electrical Acoustical ExpandedFrequency Frequency Free-field Uncertainty Wi

Página 87

Hand-held Analyzer Type 2250 –Instruction Manual62A.3 Diffuse-field Frequency ResponsesDiffuse-field frequency responses with Z-frequency-weighting: T

Página 88

APPENDIX ATables63Nominal Exact Actuator Micr. FF Micr. DF Electrical Reference Acoustical ExpandedFrequency Frequency Response Correction Correction

Página 89

Hand-held Analyzer Type 2250 –Instruction Manual64Nominal Exact Microphone Expanded Influence of Expanded Electrical Acoustical ExpandedFrequency Fre

Página 90

Hand-held Analyzer Type 2250 –Instruction Manual21.2 System Overview1.2.1 IntroductionThis Instruction Manual describes the Type 2250 Hand-held Analyz

Página 91

APPENDIX ATables65Nominal Exact Typical 4189 Expanded Influence of Expanded Electrical Acoustical ExpandedFrequency Frequency Response Uncertainty Wi

Página 92

Hand-held Analyzer Type 2250 –Instruction Manual66A.4 Directional ResponsesDirectional responses, including sensitivity variations of equipment at var

Página 93

APPENDIX ATables67Table A.11 Directional response for Microphone Type 4189 only, 4000 Hz – 10600 Hz.FrequencyAngle 4000 Hz 4500 Hz 5000 Hz 5600 Hz 630

Página 94

Hand-held Analyzer Type 2250 –Instruction Manual68Table A.12 Directional response for Microphone Type 4189 only, 11200 Hz – 20000 Hz.FrequencyAngle 11

Página 95

APPENDIX ATables69Table A.13 Sensitivity variations of Microphone Type 4189 (only) at sound incidence angles within ±θ° from thereference direction.–

Página 96

Hand-held Analyzer Type 2250 –Instruction Manual70Table A.14 Influence of Hand-held Analyzer body on directional response for Hand-held Analyzer Type

Página 97

APPENDIX ATables71Table A.15 Influence of Hand-held Analyzer body on directional response for Hand-held Analyzer Type 2250 (includ-ing Microphone Type

Página 98

Hand-held Analyzer Type 2250 –Instruction Manual72Table A.16 Influence of Hand-held Analyzer body on directional response for Hand-held Analyzer Type

Página 99

APPENDIX ATables73Table A.17 Influence of Hand-held Analyzer body on directional response for Hand-held Analyzer Type 2250 (in-cluding Microphone Type

Página 100 - APPENDIX A

Hand-held Analyzer Type 2250 –Instruction Manual74Table A.18 Influence of Hand-held Analyzer body on directional response for Hand-held Analyzer Type

Página 101 - Instruction Manual

CHAPTER 1Introduction31.3 Hardware SetupThis section provides an overview of the hardware components used with Type 2250 Hand-held Ana-lyzer, to fulfi

Página 102

APPENDIX ATables75Table A.19 Influence of Hand-held Analyzer body on directional response for Hand-held Analyzer Type 2250 (in-cluding Microphone Type

Página 103

Hand-held Analyzer Type 2250 –Instruction Manual76Table A.20 Directional response for Hand-held Analyzer Type 2250 (including Microphone Type 4189) me

Página 104

APPENDIX ATables77Table A.21 Directional response for Hand-held Analyzer Type 2250 (including Microphone Type 4189) measured ina plane parallel to the

Página 105 - 500 Hz – 3550 Hz

Hand-held Analyzer Type 2250 –Instruction Manual78Table A.22 Directional response for Hand-held Analyzer Type 2250 (including Microphone Type 4189) me

Página 106 - 4000 Hz – 10600 Hz

APPENDIX ATables79Table A.23 Directional response for Hand-held Analyzer Type 2250 (including Microphone Type 4189) measured ina plane parallel to the

Página 107 - 11200 Hz – 20000 Hz

Hand-held Analyzer Type 2250 –Instruction Manual80Table A.24 Directional response for Hand-held Analyzer Type 2250 (including Microphone Type 4189) me

Página 108

APPENDIX ATables81Table A.25 Directional response for Hand-held Analyzer Type 2250 (including Microphone Type 4189) measured ina plane parallel to the

Página 109

Hand-held Analyzer Type 2250 –Instruction Manual82Table A.26 Sensitivity variations of Hand-held Analyzer Type 2250 (including Microphone Type 4189)

Página 110 - Appendix B

APPENDIX ATables83Table A.27 Influence of Windscreen UA 1650 on directional response of Hand-held Analyzer Type 2250 (includingMicrophone Type 4189),

Página 111

Hand-held Analyzer Type 2250 –Instruction Manual84Table A.28 Influence of Windscreen UA 1650 on directional response of Hand-held Analyzer Type 2250 (

Página 112 - APPENDIX B

Hand-held Analyzer Type 2250 –Instruction Manual4Fig.1.1 Hardware Overview UA1317MicrophoneHolderUA0801Small Tripod(or UA 0587)Sound Level Calibr

Página 113

APPENDIX ATables85Table A.29 Influence of Windscreen UA 1650 on directional response of Hand-held Analyzer Type 2250 (includingMicrophone Type 4189),

Página 114

Hand-held Analyzer Type 2250 –Instruction Manual86Table A.30 Directional response for Microphone Type 4189 only, with Windscreen UA 1650 fitted, 500 H

Página 115

APPENDIX ATables87Table A.31 Directional response for Microphone Type 4189 only, with Windscreen UA1650 fitted, 4000 Hz – 10600 Hz.FrequencyAngle 4000

Página 116 - B.3 Irrelevant Topics

Hand-held Analyzer Type 2250 –Instruction Manual88Table A.32 Directional response for Microphone Type 4189 only, with Windscreen UA1650 fitted, 11200H

Página 117

APPENDIX ATables89Table A.33 Sensitivity variations of Microphone Type 4189 only, with Windscreen UA 1650 fitted, at sound inci-dence angles within ±

Página 118

Hand-held Analyzer Type 2250 –Instruction Manual90Table A.34 Directional response for Hand-held Analyzer Type 2250 (including Microphone Type 4189), w

Página 119

APPENDIX ATables91Table A.35 Directional response for Hand-held Analyzer Type 2250 (including Microphone Type 4189), with Wind-screen UA 1650 fitted a

Página 120

Hand-held Analyzer Type 2250 –Instruction Manual92Table A.36 Directional response for Hand-held Analyzer Type 2250 (including Microphone Type 4189), w

Página 121

APPENDIX ATables93Table A.37 Directional response for Hand-held Analyzer Type 2250 (including Microphone Type 4189), with Wind-screen UA 1650 fitted a

Página 122

Hand-held Analyzer Type 2250 –Instruction Manual94Table A.38 Directional response for Hand-held Analyzer Type 2250 (including Microphone Type 4189), w

Comentários a estes Manuais

Sem comentários